Arkansas Insulation Code & R-Value Requirements

The short answer

Arkansas uses the 2009 International Energy Conservation Code (IECC) for homes, with state amendments, and it has been mandatory statewide since January 1, 2015 (U.S. DOE). Most counties are in climate zone 3A; 12 northern counties are in zone 4A (PNNL). Under the 2009 IECC table, ceilings need R-30 in zone 3 and R-38 in zone 4 (ICC, 2009 IECC Table 402.1.1). Always confirm with your local building department, because the Arkansas amendments can change details.

Which code applies in Arkansas?

The U.S. Department of Energy lists Arkansas’s current residential code as the 2009 IECC with state amendments, effective January 1, 2015, with mandatory statewide enforcement (U.S. DOE). The code applies to new homes and, in general, to additions and alterations. It sets minimums; you can always insulate above them.

Climate zones 3A and 4A

The PNNL county guide places these 12 Arkansas counties in zone 4A: Baxter, Benton, Boone, Carroll, Fulton, Izard, Madison, Marion, Newton, Searcy, Stone and Washington. The rest of the state is zone 3A (PNNL). The “A” means a moist climate.

R-value table (2009 IECC prescriptive)

ComponentZone 3Zone 4 (except Marine)
CeilingR-30R-38
Wood frame wallR-13R-13
FloorR-19R-19
Crawl space wallR-5 continuous or R-13 cavityR-10 continuous or R-13 cavity
Basement wallR-5 continuous or R-13 cavityR-10 continuous or R-13 cavity
Slab edgeR-0R-10, 2 ft

Source: ICC, 2009 IECC Table 402.1.1. R-values are minimums. The table notes that basement wall insulation is not required in warm-humid locations. Arkansas amendments may change some values, so check locally.

How spray foam fits the code

Spray foam is rated by R-value per inch, so the thickness decides whether a wall or roof meets the table. Ask the contractor to write the foam type, finished thickness and total R-value on the quote. Foam inside a home also usually needs a fire-rated covering or coating where the code requires it; see is spray foam flammable. For roofline foam, see roof deck spray foam.

Existing homes and upgrades

If you are not building or remodeling, the code usually does not force you to add insulation. Many owners still use the table as a target. Utility programs may set their own levels; for example, Entergy’s program guidebook mentions bringing qualifying ceilings up to R-38 (Entergy guidebook). See our Arkansas rebates guide.

Frequently asked questions

Yes. DOE lists the 2009 IECC with state amendments as the current Arkansas residential code, effective January 1, 2015 (U.S. DOE).

Under the 2009 IECC table, ceilings need R-30 in zone 3 and R-38 in zone 4 (ICC, 2009 IECC Table 402.1.1). Check local amendments.

Baxter, Benton, Boone, Carroll, Fulton, Izard, Madison, Marion, Newton, Searcy, Stone and Washington (PNNL).

Usually not, unless you are adding on or remodeling. Your local building department can confirm what applies to your project.

It should. Ask for the foam type, finished thickness and total R-value in writing so you can compare quotes.

Request an estimate

Want a quote that lists thickness and R-value? Send us your project and we pass it to an independent partner contractor for a written estimate.